| Norma | Descrição | Ratificação | Origem | Designação documental |
| EN 12015 | Electromagnetic compatibility -Product family standard for lifts , escalators and passenger conveyors - Emission | 1998 | ||
| EN 12016 | Electromagnetic compatibility -Product family standard for lifts , escalators and passenger conveyors - Immunity | 1998 | ||
| EN 301169-1 | Equipment pratice;Engineering requirements for outdoor enclosures; Part1: Complete systems | 1998-03 | ||
| EN 301169-2 | Equipment pratice;Engineering requirements for outdoor enclosures; Part2: Miscellaneous enclosures | 1998-03 | ||
| EN 50083-8 | Cabled networks for televion signals, sound signals and interactive; Part 8 : Electromagnetic compatibility for networks. | 1998 | ||
| EN 50174-1 | Information technology - Cabling installation Pat1: Specification and quality assurance. | 1998 | ||
| EN 50174-2 | Information technology - Cabling installation Pat2:Installation planning and practices inside buildings. | 1998 | ||
| EN 50279 | Visual Display Units - Measuring methods for low frequency electric and magnetic near fields. | 1997 | ||
| EN 50293 | Electromagnetic compatibility - Road Traffic signal systems Product standard. | 1997 | ||
| EN 50310 | Application of equipotential bonding and earthing at premises with information technology eqipment. | 1998 | ||
| EN 55013 | Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and associated equipment. | 1997 | ||
| EN 55020 | Electromagnetic cimmunity of broadcast receivers and associated equipment. | 1998 | ||
| EN 61000-1-2 Ed.1 | Electromagnetic Compatibility (EMC) | 1998 | 77/182/CD | 77/197/CD |
| 77/197/CD | 77/202/CD | |||
| EN 61000-1-3 TR3 | The effects on high- altitude EMP (HEMP) on civil equipment and systems. | 1999 | 77C/51/NP | 77C/57A/RVN |
| 77C/51/NP | 77C/57/RVN | |||
| 77C/226/NP | 77A/243/RVN | |||
| EN 61000-2 | Immunity to High Altitude Electromagnetic Pulse (HEMP) | 1998 | 77C/43/CDV | 77C/56/RVC |
| 77C/43/CDV E 77C/56/RVC | 77C/61/FDIS | |||
| EN 61000-2-11-Ed1 | Immunity to High Altitude Nuclear Electromagnetic Pulse (HEMP) | 1998 | 77C/41/CD e 77C/50/CC | 77C/59/CDV |
| EN 61000-2-12 | Low Frequency Phenomena | 1997 | 77A/174/CDV | 77A/229/RVC |
| EN 61000-3 | Electromagnetic Compatibility (EMC) - Part 3 : Limits - Section 1 Overview of Emission Standars and Guides. Technical Report. | 1997 | 77A/226/NP | |
| EN 6100-3-2 | Amend 61000-3-2 to clarity Class D membership and limits with fluctuating loads. | 1997 | 77A/223/NP | |
| EN 61000-3-2 f2 Ed.2 | Electromagnetic Compatibility (EMC) - Part 3 : Limits - Section 2 limits for harmonics current emissions ( equipment input current <16A per phase )- limits for professional equipment with input power >1000W. | 1998 | 77A/219/CD | |
| EN 61000-3-9 | Electromagnetic Compatibility (EMC) - Part 3-9 : Limits for interharmonic current emissions ( equipment with input power<16A perphase and prone to produce interharmonics by design). | 1999 | 77A/196/CD | 77A/254/CC |
| EN 61000-3-11 | Electromagnetic Compatibility (EMC) - Part 3-11 : Limitation of voltage change, voltage flutuations and flicker in public low - voltage supply systems, for equipment with rated current <= fluctuations 75A and subject to conditional connection. | 1998 | 77A/183/CD e 77A/234/CC | 77A/249/CDV |
| EN 61000-3-12 | Standar to be developed " limits for harmonics produced by equipment connected to public low- voltage systems with input current above 16A/ phase. | 1995 | 77A/225/NP | 77A/251/RVN |
| EN 61000-3-2 | Control methods | 1995 | 77A/230/NP | |
| EN 61000-3-2-A3 Ed.1 | Amendment related to subclause 6,1 and to professional equipment >1Kw to IEC 61000-3-2:1995 . | 1995 | 77A/219/CD e 77A/230NP | 77A/262/CDV |
| En 61000-3-2/a2/f4/Ed10 | Parte 3: Limits - Section 2: Limits for harmonic current emissions (equipment input current 16A per phase ) - Limits for self-ballasted lamps. | 1997 | 77A/228/RVD | |
| EN 61000-3-2-A4 Ed1 | Phenomene basse frequence | 1995 | 77A/219/CD | 77A/261/CDV |
| EN 61000-3-2-Ed2 | Revision of 61000-3-2 | 1995 | 77A/242/NP | 77A/253/RVN |
| EN: 61000-3-2 f2 Ed2 | Electromagnetic Compatibility (EMC) - Part 3 : Limits - Section 2 : Limits for harmonics current input <16A per phase ) - Limits for professional equipment with input power >1000W. | 1996 | 77A/219/CD | 77A/255/CC |
| EN 61000-3-2 f3 Ed.2 | Amendment to IEC 61000-3-2 to clarify Class D membership and limits with flutation loads. | 1996 | 77A/223/NP | 77A/237/RVN |
| EN 61000-3-2 f4 Ed 2 | Amendment to IEC 61000-3-2 1995,Clause 6,1 : Control methods. | 1995 | 77A/230/NP | 77A/247/RVN |
| EN 61000-3-3 | Amendment to IEC 61000-3-3 and 61000-3-5 to take into account the start -up of equipment including motors. | 1997 | 77A/224/NP | |
| EN 61000-3-3A1 f3 Ed.1 e 61000-3-5 A1 Ed.1 | Amendment to IEC 61000-3-3 and 61000-3-5 to take into account the start -up of equipment including motors. | 1997 | 77A/224/NP | 77A/238/RVN |
| EN 61000-3-3 a1 f2 Ed.1 | Low Frequency phenomena | 1998 | 77A/140/NP e 77A/149/RVN 77A(NL) 5/NP e 77A ( Secretariat ) 115/RVN | 77A/248/CD |
| EN 61000-3-4 | Standard to be developed " Limits for harmonics produced by equipment connected to public low-voltage systems with input current above 16A. | 1997 | 77A/225/NP | |
| EN 61000-3-9 | Electromagnetic Compatibility (EMC) - Part 3 : Limits - Section 2 : Limits for interharmonics current emissions ( equipment withinput power <16A per phase and prone to produce interharmonics by design). | 1998 | 77A/196/CD | 77A/254/CC |
| EN 61000-4 | Hemp simulator compendium | 1998 | 77C/64/NP | |
| EN 61000-4-1 Ed2. | Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement Techniques - Selection 1: Overview of IEC 61000-4 series . Basic EMC Publication. | 77/200/NP | ||
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement Techniques - Selection 1: Overview of IEC 61000-4 series . Basic EMC Publication. | 77/188/CD | 77/198/CC | ||
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement Techniques - Selection 1: Overview of IEC 61000-4 series . Basic EMC Publication. | 77/188/CD e 77/200/NP | 77/207/CDV | ||
| EN 61000-4-14 Ed1 | Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement Techniques - Voltage flutuation immunity test. | 77A/214/CDV 77A/246/RCV | 77A/263/FDIS | |
| EN 61000-4-15 | Amendment to include the 120-V lamp specification of the IEC 61000-4-15 | 77A/233/NP | ||
| EN 61000-4-2 | Revision of IEC 61000-4-2 | 77B/225/NP | ||
| Revision of IEC 61000-4-2 | 77B/225/NP | 77B/236/RVN | ||
| EN 61000-4-2/A1/ Ed.1 | Result of the voting | 77B/226/RVD | ||
| EN 61000-4-2-f1 Ed1 | High Frequency phenomena | 77B/189/NP 77B/197/RVN | 77B/231/CD | |
| High Frequency phenomena- Definition of accessible parts under normal operating conditions. | 77B/231/CD | 77B/242/CC | ||
| EN 61000-4-2-f3 Ed1 | High Frequency phenomena- Test set-up for portable and / or double insulated table top equipment. | 77B/191/NP 77B/199/RVN | 77B/232/CD | |
| High Frequency phenomena- Test set-up for portable and / or double insulated table top equipment. | 77B/232/CD | 77B/243/CC | ||
| EN 61000-4-25- Ed1 | Imunity to high altitude nuclear electromagnetic | 77C/46/CD | 77C/55/CD | |
| Imunity to high altitude nuclear electromagnetic pulse (Hemp) requirements and test methods for equipment and systems | 77C/55/CD | 77C/67/CD | ||
| Electromagnetic compatibility (EMC) - Part 4 : Testing and measurement tecniques - Section 25 : HEMP requirements and test methods for equipment and systems . Basic EMC Publication. | 77C/55/CD | 77C/62/CC | ||
| EN 61000-4-27- Ed1,0 | Phenomene basse frequence | 77A/146/CD 77A/231/CC | 77A/250/CDV | |
| EN 61000-4-28- Ed1,0 | Electromagnetic compatibility (EMC) - Part 4-28 : Testing and measurement tecniques - Variation of power frequency , Immunity test. | 77A/157/CD 77A/213/CC | 77A/235/CDV | |
| EN 61000-4-3/A1 | Result of the voting | 77B/238/RVD | ||
| EN 61000-4-3 A1 f1- Ed1 | Amendment to IEC 61000-4-3 : Radiated , radio- frequency, electromagnetic field imminity Test - Test for immunity to RF emissions from digital radio Telephones. | 77B/203/CDV | 77B/227/RVC | |
| Amendment 1 to IEC 61000-4-3 | 77B/203/CDV | 77B/234/FDIS | ||
| Amendment 2 to IEC 61000-4-3 | 77B/204/CDV 77B/227/RVC | 77B/235/FDIS | ||
| EN 61000-4-3 A1 f2- Ed1 | Amendment to IEC 61000-4-3 : Radiated , radio- frequency, electromagnetic field imminity Test - Sub-clause 6,2 : Calibration of field. | 77B/204/CDV | 77B/228/RVC | |
| EN 61000-4-3 A2 f2- Ed1 | Amendment to IEC 61000-4-3 : Annex XX : Alternative method - Reverberation chamber chamber method. | 77B/215/CD | 77B/233A/CC | |
| EN 61000-4-3 A2 | Result of the voting | 77B/239/RVD | ||
| EN 61000-4-7 Ed2 | Revision of IEC 61000-4-7 - Electromagnetic compatibility (EMC) - Part 4-7 : Testing and measurement tecniques - General guide on harmonics and interharmonics measurements and instrumentation , for power supply systems and equipment connected Thereto. | 77A/197/CD | 77A/239/CC | |
| EN 61000-4-13 Ed1 | Electromagnetic compatibility (EMC) - Part 4-13 : Testing and measurement tecniques - Test for immunity to harmonics and interharmonics including mains signalling at a. c. power port - Basic EMC Publication. | 77A/215/CD | 77A/240/CC | |
| EN 61000-4-14 | Electromagnetic compatibility (EMC) - Part 4-14 : Testing and measurement tecniques - Voltage fluctuations, immunity test. Basic EMC publication. | 77A/214/CDV | 77A/246/RVC | |
| EN 61000-4-14/Ed1 | Electromagnetic compatibility (EMC) - Part 4-14 : Techniques d,essai et de mesure - Essai dímmunité aux fluctuations de tension. | 77A/263/FDIS | ||
| EN 61000-4-17 | Electromagnetic compatibility (EMC) - Part 4-17 : Techniques and measuring techniques - Ripple on d.c input power port, immunity test .Basic EMC Publication. | 77A/207/CDV | 77A/245/RCV | |
| EN 61000-4-27 | Electromagnetic compatibility (EMC) - Part 4: Techniques and measuring techniques - Section 27 . Unbalance, immunity test. | 77A/176/CD | 44A/231/CC | |
| EN 61000-4-29 | Electromagnetic compatibility (EMC) - Part 4-29 : Techniques and measuring techniques - Voltage dips , short interruptions and voltage variations on d.c. input ports, Immunity tests. | 77A/206/CD | 77A/236/CC | |
| EN 61000-4-3 | Amendment to 61000-4-4 : Radiated , radio - frequency , electromagnetic field immunity test methods above 1 GHZ. | 77B/237A/NP | ||
| Amendment to 61000-4-3 : Electromagnetic compatibility - Part4 : Testing and measurment techniques - Section 3 : Radiated , radio - frequency , electromagnetic field immunity test. | 77B/240A/NP | |||
| Revision of IEC 61000-3-2 | 77A/242/NP | |||
| EN 61000-4-3 A2 f1 Ed1 | Amendment to TEC 61000-4-3- Annex D. Other test methods - TEM cells and striplines. | 77B/212/CD | 77B/229/CC | |
| EN 61000-4-3 A2 f2 | Amendment to TEC 61000-4-3- Annex xx : Alternative method - Reverberaton chamber method. | 77B/215/CD | 77B/233/CC | |
| EN 61000-4-3 | Amendment to TEC 61000-4-3: Radiated, radio - frequency, electromagnetic field immunity test methods above 1GHZ. | 77B/237/NP | ||
| EN 61000-4-31 Tr2 | Electromagnetic compatibility (EMC) - Part 4-31: Testing and measurement techniques - Measurements in the frequency range 2 Khz to 9 Khz. | 77A/198/CD | 77A/241/CC | |
| EN 61000-5-2 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines- Section 2 : Earning and cabling. | 1997 | ||
| EN 61000-5-3 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines- HEMP protecion conceps. | 1998 | 77C/61000-5-3 | 77C/58/CDV |
| EN 61000-5-7 | Immunity to High Altitude Nuclear Electromagnetic Pulse (HEMP) | 1998 | 61000-5-7 | 77C/54/CD |
| Degrees of protection against electromagnetic disturbances provided by enclosures (EM codes) | 1998 | 77C/54/CD | 77C/63/CC | |
| Electromagnetic compatibility (EMC) - Part 5-7:Degrees of protection against electromagnetic disturbances provided by enclosures (EM code). | 77C/6100-5-7 | 77C/66/CDV | ||
| EN 61000-6-2-Ed1 | Electromagnetic compatibility (EMC) - Part 6:Generic standards - Section 2 : Immunity for industrial environments. | 77/195/CDV | 77/205/RVC | |
| Electromagnetic compatibility (EMC) - Part 6-2:Generic standards - Immunity for industrial environments. | 77/195/CDV 77/205/RVC | 77/208/FDIS | ||
| EN 61000-6-5 | Automation and control apparatus for generating stations and high - voltage substations Electromagnetic Compatibility - Immunity requirements. | 77/199/NP | ||
| Automation and control apparatus for generating stations and high - voltage substations Electromagnetic Compatibility - Immunity requirements. | 77/199/NP | 77/203/RVN | ||
| EN 60966-1/Ed2 | IEC 610966-1: Radio - frequency and coaxial cable assemblies - Part 1 . Generic specification - General requirements nd test methods. | 46A/308/CDV 46A/326/RVC | 46A/343/FDIS | |
| EN 61644-1 Ed1 | Surge protective devices connected to telecomunications and signalling networks - Part 1 : Performance requirements and testing methods. | 37A/61/CDV 37A/68A/RVC | 37A/80/CDV | |
| EN 60950/Ed3 | Safety of information tecnhnology equipment | 74/484/CDV 74/492/RVC | 74/498/FDIS |